PDF files require Acrobat Reader
to view them.
Click above to download it
for free.
|
 |

MCR Portable Series -
Power Line Conditioning with Voltage Regulation
| The
MCR and MPC provide excellent noise filtering and surge protection to protect connected equipment from
damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to
Sola/Hevi-Dutys patented ferroresonant design, they can increase the actual Mean Time Before Failure
(MTBF) of protected equipment. These units are a perfect choice where dirty power caused
by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because
of damaged equipment.
On this page: Features, Applications, Specifications, Back Panels, Selection Tables
|

|
| Printable
versions of the following sections are available by selecting one the pdf files to the
left. |
 |

|
- Noise
attenuation
- 120 dB common mode
- 60 dB transverse mode
|
- Surge
suppression tested to ANSI/IEEE C62.41 Class A & B Waveform:
<10 V let through typical
|
|
|
- Galvanic
isolation provides exceptional circuit protection
|
- Point-of-use
Protection
-
Cord & Plug Connected
- Easy & Flexible Installation
|
|
|
|
- ±3%
output voltage regulation
|
|
Parameter
|
Condition |
Value |
|
Input
|
| Voltage
|
Continuous
at full load
(lower input voltage possible at lighter load) |
+10%
to -20% of nominal |
| For
temporary surges or sags |
+20%
to -35% of nominal |
| Current |
at
Full Load & 80% of nominal input voltage |
Iin
@
(VA/.89) / (Vin * 80%) |
| Frequency |
See
the Operating Characteristics
pdf for details. |
50
or 60 Hz depending on model |
|
Output
|
| Line
Regulation |
Vin
>80% and <110% of nominal |
±5%
for 50 Hz
±3% for 60 Hz |
| Overload
Protection |
At
Nominal Input Voltage |
Current
limited at 1.65 times rated current |
| Noise
Attenuation |
-Common
Mode
-Transverse Mode |
120
dB
60 dB |
Output
Harmonic
Distortion |
At
full load within input range |
3%
total RMS content at full load |
| Let-through |
ANSI/IEEE
C62.41 Class A & B Waveform |
<10
V Typical |
|
General
|
| Efficiency |
at
Full Load |
92%
Typical |
| Storage
Temperature |
Humidity
<95% non-condensing |
-20o
to 85oC |
| Operating
Temperature |
-20o
to 40oC |
| Audible
Noise |
n |
35
dBA to 65 dBA |
| Approvals |
60
Hz Models
50 Hz Models
|
CE
(EMC & LVD)
UL10121;
CSA (or cUL)1
|
| Warranty |
n |
10
+ 2 Years |
|
Note:
1
- Depending on model, see Selection
Tables to confirm agency approvals for specific model
numbers.
|

|

|
60 Hz, 70 - 1000 VA,
(4) 5-15R Receptacles |
60 Hz, 2000 - 3000 VA,
(4) 5-15R and (1) L5-30R Receptacle |
| Group A - MCR
Portable Series, 60 Hz
|

|
UL
File:
|
 |
| VA |
Catalog
Number |
Voltage
Input/Output |
Height
(inch) |
Width
(inch) |
Depth
(inch) |
Ship
Weight
(lbs) |
Receptacle (No.)
Type (NEMA) |
Plug
(NEMA) |
| 70 |
63-13-070-6 |
120 |
6 |
7 |
9 |
18 |
(4) 5-15R |
5-15P |
| 150 |
63-13-115-6 |
120 |
6 |
7 |
9 |
21 |
(4) 5-15R |
5-15P |
| 250 |
63-13-125-6 |
120 |
6 |
7 |
9 |
26 |
(4) 5-15R |
5-15P |
| 500 |
63-13-150-6 |
120 |
9 |
9 |
16 |
32 |
(4) 5-15R |
5-15P |
| 750 |
63-13-175-6 |
120 |
9 |
9 |
16 |
64 |
(4) 5-15R |
5-15P |
| 1000 |
63-13-210-6 |
120 |
9 |
9 |
16 |
69 |
(4) 5-15R |
5-15P |
| 1500* |
63-13-215-6 |
120 |
11 |
11 |
17 |
95 |
(6) 5-15R |
5-20P |
| 2000** |
63-13-220-6 |
120 |
11 |
11 |
17 |
115 |
(4) 5-15R, (1) L5-30R |
L5-30P |
| 3000** |
63-13-230-6 |
120 |
11 |
11 |
17 |
143 |
(4) 5-15R, (1) L5-30R |
5-50P |
*This unit is cULus
certified.
**This unit is not CSA certified. |
|
 |