PDF files require Acrobat Reader
to view them.
Click above to download it
for free.
|
 |

|
|
SDN Series Power Supply (Single
and Three Phase Units, 60-960 Watts) |
| The
SDN DIN Rail power supply products provide industry leading performance.
Sag immunity, transient suppression and noise tolerant, the
SDN series ensures compatibility in demanding applications.
Power factor correction to meet European directive, hazardous
location approvals and optional redundant accessories allow
the SDN series to be used in a wide variety of applications.
Wide operation temperature range, high tolerance to shock and
vibration and reliable design make the SDN series the definition
of DC power quality. |
|
A printable version of the following sections is available by selecting the
pdf file to the left.
- Industrial/Machine
control
|
|
|
|
|
|
|
|
|
|
- Semiconductor Fabrication Equipment
|
|
|
|
- Chassis
Mount Bracket (SDN-PMBRK2)
|
Description
|
Catalog
Number |
|
SDN
2.5-24-100P
|
SDN
4-24-100LP |
SDN
5-24-100P |
SDN
10-24-100P |
SDN
20-24-100P |
|
Input
|
Nominal
Voltage |
115/230
VAC user select (no manual required)
|
|
-AC Range |
85-132/176-264
VAC
|
|
-DC Range |
90-375
VDC
|
210
- 375 VDC |
N/A
|
|
-Frequency |
47
- 63 Hz
|
| Nominal Current1 |
1.3
A / 0.7 A
|
1.8
A / 0.9 A |
2.2
A / 1.0 A |
5
A / 2 A typical |
9
A / 3.9 A |
-Inrush
current max. |
typ. <25 A
|
typ.
<20 A |
typ.
<40 A |
Efficiency
(Losses2) |
>87.5%
typ
(8.6 W)
|
>88%
typ
(13.1 W) |
>88%
typ (16.4 W) |
>88%
typ
(32.7 W) |
>90%
typ
(48 W) |
Power
Factor
Correction |
Units
fulfill EN61000-3-2
|
|
Output
|
| Nominal Voltage |
24
VDC (22.5
- 28.5 VDC Adj.)
|
|
-Tolerance |
<±2%
overall (combination
line, load, time and temperature related changes)
|
|
-Ripple3 |
<
50 mVpp
|
| Nominal Current |
2.5
A (60 W)
|
3.8
A (92 W)
|
5
A (120 W)
|
10
A (240 W) |
20
A (480 W)
|
| -Peak
Power4 |
1.6x
Nominal Current
< 2 sec.
|
4.2
A max at 23.8V
|
6
A
2x Nominal Current
< 2 sec.
|
12
A
2x Nominal Current
< 2 sec.
|
25
A
2x Nominal Current
< 2 sec.
|
| -Current Limit
|
Fold
Forward (Current rises, voltage drops to maintain constant
power during overload up to max peak current) |
| Holdup
Time |
>
50 ms
|
>
110 ms
|
>
100 ms
|
>
20 ms
|
| Parallel Operation |
Single
or Parallel use is selectable via Front Panel
|
|
General
|
EMI
-Emissions |
EN50081-1,-2
Class B EN55011, EN55022 Radiated and Conducted including
Annex A. |
|
-Immunity |
EN50082-1,
-2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6
Level 3; EN61000-4-4 Level 4
input and Level 3 output; EN61000-4-5 Isolation Class
4, EN61000-4-11; Transient resistance according to VDE 0160/W2
over entire
load range. |
| Approvals |
EN60950;
EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE
(LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC60079-15
(Class 1, Zone 2, Hazardous Location, Groups A, B, C,
D, w/T3A temp class up to 60oC Ambient) SEMI F47
Sag Immunity. SDN2.5 &
SDN4 -UL60950 testing to include approval as NEC Class 2 power
supply acc. to NFPA 70 art. 725-41 (a)(2). |
| Temperature |
Storage:
-25oC...+85oC Operation. -10o-60oC
full power with operation to 70oC possible with
a linear derating to half power from 60oC
to 70oC (Convection cooling, no forced air required).
Operation up to 50% load permissable with sideays or front
side up mounting orientation.
The relative humidity is 95% RH, noncondensing; IEC68-2-2,
68-2-3. For operation below -10oC, contact Technical
Services. |
| Warranty |
5
years
|
General
Protections/
Safety |
Protected
against short-circuit, overload, open-circuit. Overvoltage
protection (OVP) for output set
>30.5 but <33 VDC, Auto Recovery.
Protection class I (IEC536), degree of protection: IP20
(IEC 529) Safe low voltage: SELV (acc. EN60950). |
Status
Indicators |
Green
LED and DC OK signal (N.O. Contacted rated 300 mA @ 60 VDC) |
|
Installation
|
| Fusing |
| -Input |
Internally
fused. External 10 A slow acting fusing for the input is recommended
for SDN2.5, 4 5 and 10P models. A 16A slow acting fuse or
time-delay circuit breaker is recommended for the SDN20
model. |
| -Output |
Outputs
are capable of providing high currents for short periods of
time for inductive load startup or switching. Fusing may be
required for
wire/loads if 2x Nominal O/P current rating cannot be
tolerated. Continuous current overload allows for reliable
fuse tripping. |
| Mounting |
Simple
snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional
screw mounting set SDN-PMBRK2 required). |
| Connections |
Input:
IP20-rated screw terminals, connector size range: 16-10 AWG
(1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for stranded conductors.
Output: Two connectors per output,
connector size range: 16-10 AWG (1.5-6 mm2) for
solid conductors. |
| Case |
Fully
enclosed metal housing with fine ventilation grid to keep
out small parts |
| -Free
Space |
25
mm above/below
25 mm left/right
10 mm in front
|
25
mm above/below
25 mm left/right
15 mm in front
|
70
mm above/below
25 mm left/right
15 mm in front
|
H
x W x D
(inches/mm) |
4.88
x 1.97 x 4.55
(124 x 50 x 116)
|
4.88
x 2.56 x 4.55
(124 x 65 x 116)
|
4.88
x 3.26 x 4.55
(124 x 83 x 116)
|
4.88
x 6.88 x 4.55
(124 x 175 x 116)
|
| Weight
(lbs/g) |
1.6
lb (725g)
|
2.4
lb (1055g)
|
3.3
lbs (1480g) |
3
lbs (1520g) |
Notes:
1.
Input current ratings are conservatively specified with low
input, line conditions, worst case efficiency and power factor.
2. Losses are heat dissipation in watts at full load, nominal
input line.
3. Ripple/noise is stated as typical values when measured
with a 20 MHz, bandwidth scope and 50 Ohm resistor.
4. All peak power is calculated at 24 Volt levels.
5. Full load, 100VAC Input @ Tamb = +25oC
|
|
Description
|
Catalog
Number
|
|
SDN
5-24-480
|
SDN
10-24-480
|
SDN
20-24-480C |
SDN
30-24-480 |
SDN
40-24-480 |
|
Input
|
| Nominal
Voltage |
1Æ
or 3Æ, 380 - 480 VAC |
1Æ
or 3Æ, 380 - 480 VAC1
|
3Æ
380-480 VAC |
|
-AC Range |
340-576
VAC
|
|
-DC Range |
450
- 820 VDC |
|
-Frequency |
47
- 63 Hz
|
| Nominal Current2 |
0.5 A |
0.8 A |
1.5 A |
2.0 A |
3.0
A |
|
-Inrush current |
typ.
< 18 A |
typ.
< 30 A |
Efficiency
(Losses2) |
>90%
typ (12 W) |
>90%
typ (48 W) |
>90%
typ (72 W) |
>90%
typ (96 W) |
Power
Factor
Correction |
Units
fulfill EN61000-3-2 |
|
Output
|
| Nominal Voltage |
24
VDC (22.5 - 28.5 VDC adj.)
|
|
-Tolerance |
<±2%
overall (combination line. load, time and temperature related
changes)
|
|
-Ripple4 |
<
50 mVpp |
| Nominal Current |
5
A (120 W)
|
10
A (240 W)
|
20
A (480 W) |
30
A (720 W)
|
40
A (960 W) |
|
-Peak Current |
6
A
2x Nominal Current
< 2 sec.
|
12
A
2x Nominal Current
< 2 sec.
|
25
A
2x Nominal Current
< 2 sec.
|
35
A
2x Nominal Current
< 2 sec.
|
45
A
2x Nominal Current
< 2 sec.
|
-Current
Limit |
Fold
Forward
(Current rises, voltage drops to maintain constant power
during overload up to max peak current)
|
| Holdup
Time |
>40
ms
|
>28
ms
|
>20
ms
|
Parallel
Operation |
5A
through 30A units may be passively paralleled by
selecting the "P" position of the switch on the unit.
The SDN40 contains active current balancing.
|
|
General
|
EMI
-Emissions
-Immunity |
EN61000-6-3, -4; Class B EN55011, EN55022
Radiated and Conducted including Annex A. |
|
EN61000-6-1, -2; EN61000-4-2 Level 4,
EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4
Level 4 input and Level 3 output; EN61000-4-5 Isolation
Class 4, EN61000-4-11; Transient resistance according to
VDE 0160/W2 over entire load range.
|
| Approvals |
CB
Scheme, EN60950; EN50178; EN60204; UL508 Listed, cULus;
UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC).
EN61000-3-2, IEC
60079-15 (Class 1, Zone 2 hazardous location, Groups IIA, IIB, IIC w/T3
temp class up to 60°C Ambient.) |
| Temperature |
Storage:
-25oC...+85oC Operation. -10o-60oC
full power with operation to 70oC possible with
a linear derating to half power from 60oC to
0oC. (Convection cooling, no forced air
required). Operation up to 50% load permissable with
sideways or front side up mounting orientation.
The relative humidity is less <90% RH, noncondensing;
IEC 68-2-2, 68-2-3. |
| Warranty |
5
years
|
General
Protection/
Safety |
Protected against continuous short-circuit,
overload, open-circuit. Protection class 1 (IEC536), degree
of protection IP20 (IEC 529) Safe low voltage: SELV
(acc.EN60950) |
| Status Indicators |
Green
LED on, when Vout = 18V or greater. |
|
Installation
|
| Fusing |
| -Input |
Internally
fused. |
| -Output |
Outputs
are capable of providing high currents for short periods of
time for inductive load startup or switching. Fusing may be
required for
wire/loads if 2x Nominal O/P current rating cannot be
tolerated. Continuous current overload allows for reliable
fuse tripping. |
| Mounting |
Simple
snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional
screw mounting set SDN-PMBRK2 required). |
| Connections |
Input:
IP20 related screw terminals, connector size range: 16-10
AWG (1.5-6 mm2) for solid conductors.
16-12
AWG (0.5-4 mm2) for stranded conductors.
Output: two connectors per output,
connector size range: 16-10 AWG (1.5 - 6 mm2) for
solid connectors. |
| Case |
Fully
enclosed metal housing with fine ventilation grid to keep
out small parts. |
| -Free
Space |
25
mm above/below
25 mm left/right
15 mm in front
|
70
mm above/below
25 mm left/right
15 mm in front
|
H
x W x D
(inches/mm) |
4.88
x 2.91 x 4.55
(124 x 73 x 116)
|
4.88 x 3.5 x 4.55
(124 x 89 x 116)
|
4.88 x 5.9 x 4.55
(124 x 150 x 116)
|
4.88 x 9.72 x 4.55
(125 x 247 x 116)
|
4.88
x 11.1 x 4.55
(125 x 282 x 116)
|
| Weight
(lbs/g) |
1.7
lbs (730g)
|
2.16 lbs (980g)
|
3.97 lbs (1800g)
|
4
lbs (2000g) |
6.6
lbs (3300g) |
Notes:
1.
For the SDN20-24-480C, single phase input is permissible but
output is derated to 75% (15 Amps @ 24 VDC).
2. Input current ratings are conservatively specified
with low input, worst case efficiency values and power factor.
3. Losses are heat dissipation in watts at full
load, nominal input line.
4. Ripple/noise is stated as typical values when
measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
|
|
|
Catalog
Number |
Dimensions |
| H |
W |
D |
| SDN
2.5-24-100P |
4.88 (124) |
1.97 (50) |
4.55
(116) |
| SDN
4-24-100LP |
4.88
(124) |
2.56 (65) |
4.55
(116) |
| SDN
5-24-100P |
4.88
(124) |
2.56
(65) |
4.55
(116) |
| SDN
5-24-480 |
4.88
(124) |
2.91
(73) |
4.55
(116) |
| SDN
10-24-100P |
4.88
(124) |
3.26
(83) |
4.55
(116) |

|
Catalog
Number |
Dimensions |
| H |
W |
D |
| SDN
20-24-100P |
4.88 (124) |
6.88
(175) |
4.55
(116) |
| SDN
10-24-480 |
4.88 (124) |
3.50
(89) |
4.55
(116) |
| SDN
20-24-480C |
4.88 (124) |
5.90
(150) |
4.55
(116) |
| SDN 30-24-480 |
4.88 (124) |
9.72 (247) |
4.55
(116) |
| SDN 40-24-480 |
4.88
(124) |
11.10 (282) |
4.55
(116) |
DIN Rail MountingSnap on the DIN Rail:
1. Tilt unit slightly backwards.
2. Put it onto the DIN Rail.
3. Push downwards until stopped.
4. Push at the lower front edge to lock.
5. Shake the unit slightly to ensure
that the retainer has locked.
|
|
|
Alternative Screwing-on:
- Using the optional SDN-PMBRK2
accessory, the unit can also be screwed onto plane surfaces
(without DIN Rail).
|
| Detachment
from DIN Rail: |
|
|
|
|
Press button downwards (to unlock)
and remove the
unit from the DIN Rail. |
Instead of snapping a Sola SDN power supply unit on the DIN Rail, you can
also attached it using the screw mounting
set SDN-PMBRK2.
This
set consists of two metal brackets which replace the existing
two aluminum profiles.Note:
You need one SDN-PMBRK2 per unit.
In addition, two screws are required per SDN-PMBRK2 (e.g. M5 x 12), which are not included
with the set.
|
|
|
|
|
|
At the unit:
- Remove the screw from the profile.
- Pull the profile outwards to remove.
|
|
|
- Push the SDN-PMBRK2
profile into the
groove as far as possible.
Secure with screw.
Note the orientation: The profile fits into the groove only as shown here. |
 |

|
For
SDN5-24-100P
and above models. |
For SDN2.5-24-100P model
|
What's New |
Products |
Cross Reference |
Technical Support |
Contact Us |
Search |
Power Supply Home
© 2000
Sola/Hevi-Duty. All Rights Reserved.
Sola/Hevi-Duty Power Supplies - Power Supply / Din Rail Products
|
 |