Silver
Line Series - Single & Multi-Output Linears
The Silver Line series follows the industry accepted
footprint for open frame, linear power supplies. Standard screw terminal connections and optional covers are offered for safety considerations.
On this page: Features, Applications,
Specifications, Selection,
Dimensions, Manuals
- Easy-to-install screw terminal connections
- Cover options
- Industry standard footprint
- Universal input and approvals (115/230 Vac)
- Low noise, extremely quiet DC output. For noise sensitive or analog circuitry
|
- Fast transient response. Ideal for test applications.
- Built-in OVP on 5 V models and optional on 12, 15 and 24 V models
- Automatic resetting overload protection
- Short circuit protected
- Two year warranty
|
| Applications |
 |
- Industrial Control Circuits and Components
- Instrumentation
- Drives
- CNC Machinery
|
- Equipment for food industry
- Microprocessor Circuits
- Analog Circuits
- Noise sensitive Circuitry and Sensors
|
| Parameter |
Condition |
Limit |
|
Input
|
| Input
Voltage |
x |
100/120/220/230/240 Vac Selectable |
| Input
Frequency |
x |
47-63
Hz |
|
Output
|
| Line
Regulation |
for
10% change |
0.05% |
| Load
Regulation |
for
50% change |
0.05% |
| Ripple |
x |
3.0
mV maximum Peak-to-Peak |
| DC
Output Adjustment Range |
x |
±5%
Minimum |
| Overvoltage
Protection |
x |
All
5-Volt outputs include build-in OVP as standard (setting is
6.2 V ±0.4 V) OVP is optionally available on other types
|
| Transient
Response Time |
at
50% Load Changes |
50
msec. |
| Overload
Protection |
|
Automatic
current limit foldback |
| Remote
Sensing |
Available
to compensate for output voltage drop on selected models
|
0.5
Vdc
|
|
General
|
| Operating
Temperature
Range |
Derate
to 40% at +70°C
|
0
to +50°C |
|
Storage
Temperature Range
|
|
-25°C
to +85°C |
| Temperature Coefficient (Typical) |
|
0.01%°C |
| Stability |
After
warm-up |
±
0.5% |
| EMI/RFI |
Linear
power supplies have inherently low conducted
and radiate noise levels
|
For
most system applications they will meet requirements
of FCC Class B and VDE 0871 for Class B
|
| Cover
Option |
Derate
power by an additional 15%
|
| Cooling |
Forced
air. 20 CFM required for full rating Derate 30% without cooling.
|
| *Specifications
are typical. Load Regulation on outputs without Remote Sense, 0.1%
typical. |
Catalog
Number |
OUTPUT
1 |
OUTPUT
2 |
OUTPUT
3 |
Case |
| SLS-05-030-1T |
5 V @ 3 A*# |
- |
- |
A
|
| SLS-05-060-1T |
5 V @ 6 A*# |
- |
- |
B1 |
| SLS-05-090-1T |
5 V @ 9 A*# |
- |
- |
C |
| SLS-05-120-1T |
5 V @ 12 A*# |
- |
- |
I2 |
| SLS12-017T1 |
12 V @ 1.7
A#
or 15 V @ 1.5 |
- |
- |
A |
| SLS-12-034T |
12 V @ 3.4 A# |
- |
- |
B1 |
| SLS-12-051T |
12 V @ 5.1 A# |
- |
- |
C |
| SLS-12-068T |
12 V @ 6.8 A# |
- |
- |
I2 |
| SLS-15-045T |
15 V @ 4.5 A# |
- |
- |
C |
| SLS-15-060T |
15 V @ 6 A# |
- |
- |
I2 |
| SLS-24-012T |
24 V @ 1.2 A# |
- |
- |
A |
| SLS-24-024T |
24 V @ 2.4 A# |
- |
- |
B2 |
| SLS-24-036T |
24 V @ 3.6 A# |
- |
- |
C |
| SLS-24-048T |
24 V @ 4.8 A# |
- |
- |
I2 |
| SLS-24-072T |
24 V @ 7.2 A# |
- |
- |
K |
| SLS-24-120T |
24 V @ 12.0 A# |
- |
- |
L |
| SLD12-1010-12T1 |
12 V @ 1
A or 15 V @ .8 A |
-12 V @ 1 A or -15 V @ .8 |
- |
H1 |
| SLD12-1818-12T1 |
12 V @ 1.8
A or 15 V @ 1.5 A |
-12 V @ 1.8
A or -15 V @ 1.5 A |
- |
D |
| SLD-12-3434-12T |
12 V @ 3.4 A# |
-12 V @ 3.4 A# |
- |
I3 |
| SLD-15-3030-15T |
15 V @ 3 A# |
-15 V @ 3 A# |
- |
I3 |
| SLD-12-6034-05T |
5 V @ 6 A*# |
12 V @ 3.4 A# |
- |
I1 |
| SLD-12-3015-05T |
5 V @ 3 A*# |
12 V@ 1.5 A |
- |
C1 |
| SLT12-20404-12T1 |
5 V @ 2 A*# |
12 V @ .4
A or 15 V @ .4 A |
-12 V @ .4
A or -15 V @ .4 A |
H2 |
| SLT12-31010-12T1 |
5 V @ 3 A*# |
12 V @ 1
A#or 15 V @ .8 A |
-12 V @ 1
A# or -15 V @ .8 A |
F |
| SLT12-61818-12T1 |
5V @ 6A*# |
12 V @1.8
A or 15 V @1.5 A |
-12 V @ 1.8 A or -15 V @ 1.5 A |
G2 |
| Over Voltage Protector (OVP) |
| SLO-12-000-1 |
6.2 V to 34
V Adjustable @ 8 V
|
For Cases B through K |
J1 |
| SLO-12-000-TB |
6.2 V to 34
V Adjustable @ 8 V
|
For Case A or Cases B through K (when used with a cover) |
J2 |
Note:
* With Built-in OVP
# With Remote Sense (R.S.)
1. 12/15 Volt models are factory set for 12 Volt operation. 15 Volt
operation is field adjustable.
What's New | Products | Cross Reference | Technical Support | Contact Us | Search