
Silver
Line Series - Single & Multi-Output Linears
The
Silver Line series follows the industry accepted footprint for open
frame, linear power supplies. Sola improves on this design by offering
standard screw terminal connections and optional covers for safety
considerations.
On this page: Features, Applications,
Specifications, Selection,
Dimensions, Manuals
- Easy-to-install
screw terminal connections
- Cover
options
- Industry
standard footprint
- Universal
input and approvals (115/230 VAC)
- Low
noise, extremely quiet DC output for noise sensitive or analog
circuitry
- Fast transient response.
Ideal for test applications.
- Built-in
OVP on 5 V models and optional on 12, 15 and 24 V models
- Automatic
resetting overload protection
- Short
circuit protected
- Two
year warranty
| Applications |
 |
- Industrial control circuits
and components
- Instrumentation
- Drives
- CNC machinery
- Equipment for food industry
- Microprocessor circuits
- Analog circuits
- Noise sensitive circuitry
and sensors
| Parameter |
Condition |
Limit |
|
Input
|
| Input
Voltage |
x |
100/120/220/230/240
VAC Selectable |
| Input
Frequency |
x |
47-63
Hz |
|
Output
|
| Line
Regulation |
for
10% change |
0.05% |
| Load
Regulation |
for
50% change |
0.05% |
| Ripple |
x |
3.0
mV maximum
Peak-to-Peak |
DC
Output
Adjustment Range |
x |
±5%
Minimum |
| Overvoltage
Protection |
x |
All
5-Volt outputs include
build-in OVP as standard
(setting is 6.2 V ±0.4 V)
OVP is optionally available
on other types
|
| Transient
Response Time |
at
50% Load Changes |
50
msec. |
| Overload
Protection |
|
Automatic
current
limit foldback |
| Remote
Sensing |
Available
to compensate
for output voltage drop
on selected models
|
0.5
VDC
|
|
General
|
Operating
Temperature
Range |
Derate
to 40% at +70°C
|
0
to +50°C |
|
Storage
Temperature Range
|
|
-25°C
to +85°C |
Temperature
Coefficient (Typical) |
|
0.01%°C |
| Stability |
After
warm-up |
±
0.5% |
| Vibration |
Method
514 |
Per
MIL-STD-810C |
| Shock |
Method
516 |
Per
MIL-STD-810C |
| EMI/RFI |
Linear
power supplies have
inherently low conducted
and radiate noise levels
|
For
most system applications
they will meet requirements
of FCC Class B and VDE 0871
for Class B
|
| Cover
Option |
Derate
power by an additional 15%
|
| Cooling |
Forced
air.
20 CFM required for full rating
Derate 30% without cooling.
|
| *Specifications
are typical. Load Regulation on outputs without Remote Sense, 0.1%
typical. |
Catalog
Number |
OUTPUT
1 |
OUTPUT
2 |
OUTPUT
3 |
Case |
| SLS-05-030-1T |
5 V @ 3 A*# |
- |
- |
A
|
| SLS-05-060-1T |
5 V @ 6 A*# |
- |
- |
B |
| SLS-05-090-1T |
5 V @ 9 A*# |
- |
- |
C |
| SLS-05-120-1T |
5 V @ 12 A*# |
- |
- |
I2 |
| SLS12-017T1 |
12 V @ 1.7
A#
or 15 V @ 1.5 |
- |
- |
A |
| SLS-12-034T |
12 V @ 3.4 A# |
- |
- |
B |
| SLS-12-051T |
12 V @ 5.1 A# |
- |
- |
C |
| SLS-12-068T |
12 V @ 6.8 A# |
- |
- |
I2 |
| SLS-15-045T |
15 V @ 4.5 A# |
- |
- |
C |
| SLS-15-060T |
15 V @ 6 A# |
- |
- |
I2 |
| SLS-24-012T |
24 V @ 1.2 A# |
- |
- |
A |
| SLS-24-024T |
24 V @ 2.4 A# |
- |
- |
B |
| SLS-24-036T |
24 V @ 3.6 A# |
- |
- |
C |
| SLS-24-048T |
24 V @ 4.8 A# |
- |
- |
I2 |
| SLS-24-072T |
24 V @ 7.2 A# |
- |
- |
K |
| SLS-24-120T |
24 V @ 12.0 A# |
- |
- |
L |
| SLD12-1010-12T1 |
12 V @ 1
A
or 15 V @ .8 A |
-12 V @ 1 A
or -15 V @ .8 |
- |
H1 |
| SLD12-1818-12T1 |
12 V @ 1.8
A
or 15 V @ 1.5 A |
-12 V @ 1.8
A
or -15 V @ 1.5 A |
- |
D |
| SLD-12-3434-12T |
12 V @ 3.4 A# |
-12 V @ 3.4 A# |
- |
I3 |
| SLD-15-3030-15T |
15 V @ 3 A# |
-15 V @ 3 A# |
- |
I3 |
| SLD-12-6034-05T |
5 V @ 6 A*# |
12 V @ 3.4 A# |
- |
I1 |
| SLD-12-3015-05T |
5 V @ 3 A*# |
12 V@ 1.5 A |
- |
C1 |
| SLT12-20404-12T1 |
5 V @ 2 A*# |
12 V @ .4
A
or 15 V @ .4 A |
-12 V @ .4
A
or -15 V @ .4 A |
H2 |
| SLT12-31010-12T1 |
5 V @ 3 A*# |
12 V @ 1
A#
or 15 V @ .8 A |
-12 V @ 1
A#
or -15 V @ .8 A |
F |
| SLT12-61010-12T1 |
5V @ 6 A*# |
12 V @ 1
A
or 15 V @ 1 A |
-12 V @ 1
A
or -15 V @ 1 A |
I4 |
| SLT12-61818-12T1 |
5V @ 6A*# |
12 V @1.8
A
or 15 V @1.5 A |
-12 V @ 1.8 A
or -15 V @ 1.5 A |
G2 |
| SLT24-30530-05T1 |
5V @ 3A* |
-5 V @ .5 A* |
24 V @ 3 A* |
G1 |
| Over Voltage Protector (OVP) |
| SLO-12-000-1 |
6.2 V to 34
V
Adjustable @ 8 V
|
For Cases B through K |
J1 |
| SLO-12-000-TB |
6.2 V to 34
V
Adjustable @ 8 V
|
For Case A or Cases B through K
(when used with a cover) |
J2 |
Note:
* With Built-in OVP
# With Remote Sense (R.S.)
1. 12/15 Volt models are factory set for 12 Volt operation.
15 Volt
operation is field adjustable.
What's New | Products | Cross Reference | Technical Support | Contact Us | Search
| Home
© 1999
SolaHD. All Rights Reserved.
|